MONITORING SAFETY RELAYS W/DELAYED OUTPUTS 4NO 1NC

440R-M23092
2038347

Sign in to view price

The MSR138DP can be connected in 3 different input wiring configurations: 1 normally closed, 2 normally closed, or 2 OSSD. When connected in the two normally closed fashion, the MSR138DP checks for cross faults across the two inputs. When connected to light curtains, the light curtain must perform the cross-fault detection. The MSR138DP has output monitoring that can accommodate either automatic/manual reset or a monitored manual reset. When configured with automatic/manual reset (jumpers on X1-X2 and X3- X4), the MSR138DP can have the reset terminals S33-S34 jumpered or can be converted to an unmonitored manual reset by adding a normally open switch in the monitoring loop (S33-S34). When configured to monitored manual reset, the MSR138DP checks the output monitoring circuit through the manual application of the reset switch. The unit cannot be reset until the timing function has completed.
allen-bradley-440r-m
  • All returns must be made within 7 days of purchase.
  • Valid receipt is required for all returns.
  • Click Here to view the return policy.
Available Shipping Methods:

Product Overview

Product ID:
2038347
Manufacturer Part Number:
440R-M23092
EAN:
10611320826712
Brand/Manufacturer
ALLEN-BRADLEY
Unit of Measure:
PCS

Specification

Depth:
45 mm
Evaluation inputs:
1-channel or 1- and 2-channel
Height:
114.5 mm
Model:
Basic device
Number of outputs, safety related, delayed, semiconductors:
0
Number of outputs, safety related, delayed, with contact:
3
Number of outputs, safety related, undelayed, semiconductors:
0
Number of outputs, safety related, undelayed, with contact:
2
Number of outputs, signalling function, delayed, semiconductors:
0
Number of outputs, signalling function, delayed, with contact:
0
Number of outputs, signalling function, undelayed, semiconductors:
0
Number of outputs, signalling function, undelayed, with contact:
0
Performance level according to EN ISO 13849-1:
Level e
Rail mounting possible:
yes
Rated control supply voltage Us at AC 50HZ:
24...24 V
Rated control supply voltage Us at AC 60HZ:
24...24 V
Rated control supply voltage Us at DC:
24...24 V
Release-delay:
1.5...30 s
Stop category according to IEC 60204:
1
Suitable for monitoring of emergency-stop circuits:
yes
Suitable for monitoring of magnetic switches:
yes
Suitable for monitoring of optoelectronic protection equipment:
yes
Suitable for monitoring of position switches:
no
Suitable for monitoring of proximity switches:
no
Suitable for monitoring of tactile sensors:
no
Type of electric connection:
Plug-in connection
Voltage type for actuating:
AC/DC
Width:
99 mm
With approval according to UL:
yes
With detachable clamps:
no
With feedback circuit:
yes
With muting function:
no
With start input:
yes