Short DescriptionMONITORING SAFETY RELAY - 1 NC AUXILIARY OUTPUT
Long DescriptionThe MSR127RTP can be connected in three different input wiring configurations: one normally closed, two normally closed, or with two PNP connections from a light curtain. When connected in the two normally closed fashion, the MSR127RTP checks for cross faults across the two inputs. When connected to light curtains, the light curtain must perform the cross fault detection. The MSR127RP has a monitored manual reset. The MSR127TP has an automatic/manual reset. Models with automatic/manual reset can have the reset jumpered or can be converted to an unmonitored manual reset by adding a normally open switch in the monitoring loop. Models with monitored manual reset provide checking of the output monitoring circuit.
Brand/Manufacturer NameALLEN-BRADLEY
Manufacturing Part Number440R-N23133
Technical Attributes