• (0)

ALTIVAR 71 VARIABLE SPEED DRIVE 18.5KW 25HP 480V

ATV71HD18N4
2104315

Sign in to view price

Frequency inverters for 3-phase synchronous and asynchronous motors from 0.37 to 630 kW
schneider-atv71hd18n4
  • All returns must be made within 7 days of purchase.
  • Valid receipt is required for all returns.
  • Click Here to view the return policy.
Available Shipping Methods:

Product Overview

Product ID:
2104315
Manufacturer Part Number:
ATV71HD18N4
EAN:
3389118064386
Brand/Manufacturer
SCHNEIDER ELECTRIC
Unit of Measure:
PCS

Specification

4-quadrant operation possible:
yes
Application in domestic- and commercial area permitted:
yes
Application in industrial area permitted:
yes
Degree of protection (IP):
IP20
Depth:
213 mm
Height:
400 mm
Integrated breaking resistance:
no
Mains frequency:
50/60 Hz
Mains voltage:
380...480 V
Max. output at linear load at rated output voltage:
18.5 kW
Max. output at quadratic load at rated output voltage:
0 kW
Max. output frequency:
599 Hz
Max. output voltage:
480 V
Nominal output current I2N:
41 A
Number of HW-interfaces RS-232:
0
Number of HW-interfaces RS-422:
0
Number of HW-interfaces RS-485:
1
Number of HW-interfaces USB:
0
Number of HW-interfaces industrial Ethernet:
0
Number of HW-interfaces other:
11
Number of HW-interfaces parallel:
0
Number of HW-interfaces serial TTY:
0
Number of analogue inputs:
2
Number of analogue outputs:
1
Number of digital inputs:
6
Number of digital outputs:
2
Number of interfaces PROFINET:
0
Number of phases input:
3
Number of phases output:
3
Relative symmetric net frequency tolerance:
5 %
Relative symmetric net voltage tolerance:
10 %
Supporting protocol for AS-Interface Safety at Work:
no
Supporting protocol for ASI:
no
Supporting protocol for BACnet:
no
Supporting protocol for CAN:
yes
Supporting protocol for Data-Highway:
no
Supporting protocol for DeviceNet:
yes
Supporting protocol for DeviceNet Safety:
no
Supporting protocol for EtherNet/IP:
yes
Supporting protocol for Foundation Fieldbus:
no
Supporting protocol for INTERBUS:
yes
Supporting protocol for INTERBUS-Safety:
no
Supporting protocol for KNX:
no
Supporting protocol for LON:
no
Supporting protocol for MODBUS:
yes
Supporting protocol for PROFIBUS:
yes
Supporting protocol for PROFINET CBA:
no
Supporting protocol for PROFINET IO:
no
Supporting protocol for PROFIsafe:
no
Supporting protocol for SERCOS:
no
Supporting protocol for SUCONET:
no
Supporting protocol for SafetyBUS p:
no
Supporting protocol for TCP/IP:
no
Supporting protocol for other bus systems:
yes
Type of converter:
I converter
Width:
230 mm
With PC connection:
yes
With control element:
yes
With optical interface:
no

Reviews

We'd like your opinion! Rate and review this item

There are no reviews from other users.

Recently Viewed