• (0)

POWERLOGIC ION9200 METER DIN MOUNT NO DISPLAY HW KIT

METSEION92030
2423023

Sign in to view price

With precision twice that of existing energy standards, the ION9000 redefines the standard for accuracy. It resolves power quality issues faster with patented disturbance tracking technology, and provides unique modularity designed to adapt to your changing energy needs, now and far into the future.
SchneiderElectric-METSEION92030_Datasheet1
  • All returns must be made within 7 days of purchase.
  • Valid receipt is required for all returns.
  • Click Here to view the return policy.
Available Shipping Methods:

Product Overview

Product ID:
2423023
Manufacturer Part Number:
METSEION92030
EAN:
3606481352309
Brand/Manufacturer
SCHNEIDER ELECTRIC
Unit of Measure:
PCS

Specification

Accuracy class according to IEC 61000-4-30:
A
Accuracy class active energy according to IEC 62053-22:
0.1S
Accuracy class reactive energy according to IEC 62053-23:
0.5S
Data evaluation according to EN 50160:
yes
Data transfer via PQDif:
yes
Degree of protection (IP), front side:
Other
Depth:
135.3 mm
Display:
None
Display resolution (horizontal):
0 px
Display resolution (vertical):
0 px
Fault record transmission via COMTRADE:
yes
Flicker according to IEC 61000-4-15:
yes
Height:
160 mm
Measurement of harmonics in frequency range 2 kHz - 9 kHz:
yes
Measurement of harmonics in frequency range 9 kHz - 150 kHz:
no
Measuring range for frequency:
45...66 Hz
Nominal voltage (Un) L-L:
100...690 V
Nominal voltage (Un) N-L:
57...400 V
Number of Ethernet-connections:
2
Number of current measurement inputs:
5
Number of digital inputs:
8
Number of digital outputs:
6
Number of voltage measurement inputs:
4
Remote display:
no
Sampling frequency for transient detection:
0.05 MHz
Supply voltage AC 50 Hz:
90...480 V
Supply voltage AC 60 Hz:
90...480 V
Supply voltage DC:
110...480 V
Supporting protocol for IEC 61850 Ethernet:
yes
Supporting protocol for MODBUS:
yes
Supporting protocol for OPC UA PubSub:
no
Supporting protocol for PROFIBUS:
no
Supporting protocol for PROFINET IO:
no
Supporting protocol for other bus systems:
yes
Voltage type (supply voltage):
AC/DC
Web server with HTTPS transfer protocol:
yes
Width:
160 mm
With Role Based Access Control (RBAC):
yes
With audit logging (audit log):
no
With firmware signature:
no
With logging of security events (security event log):
yes
With transient detection:
yes